Features
- Corona Sensor, Proven Technology
- MPC circuit technology and the modern digital signal processing monitor check the probe tip up to 2,000 times per second
- Detects all halogen refrigerants, including A2L refrigerants
- Audible alarm with variable frequency
- 14" long, flexible, stainless steel hose with a Teflon liner
- Handle with rubber padding
- Constant Current Display
- Power supply: 3 V DC, 2 “C” alkaline batteries (included)
- Sensor life: approx. 20 hours (2 sensors included)
- Operating temperature: -20 °C to 52 °C
- The product is shipped in a plastic case with a custom-fit mount
- CE Certified
Specifications
|
Sensitivity |
< 3 g per year |
|
Mechanical Pump |
yes |
|
Visual Leak Size |
18 (three-color) |
|
Sensitivity Levels |
7 |
|
Reset via |
yes |
|
Mute |
yes |
|
Battery Test Function |
Voltage Display |
|
Battery lifetime, operating time, approx. |
about 30 hours |
Optional Accessories
|
Maintenance Kit (3 sensors with protective caps) |
TIF XP-2 |
Refrigerants
|
CFC |
e.g. R12 |
|
HCFC |
e.g. R22, 502 |
|
HFC |
e.g. R134a, 404a, 125, 410A |
|
Miscellaneous |
e.g. AZ-50, HP 62, MP 39, R1234yf, R32 |